I have two constant volume gas thermometers, one with an ideal gas pv=RT and the other following the Van der Waals equation (p+av2)(v−b)=RT. They are calibrated using the freezing point and the boiling point of water. Will they show the same temperatures?

Kenna Stanton

Kenna Stanton

Answered question

2022-11-03

I have two constant volume gas thermometers, one with an ideal gas p v = R T and the other following the Van der Waals equation ( p + a v 2 ) ( v b ) = R T. They are calibrated using the freezing point and the boiling point of water. Will they show the same temperatures?\

Answer & Explanation

cenjene9gw

cenjene9gw

Beginner2022-11-04Added 13 answers

Yes they will show the same temperature.
For the ideal gas:
The temperature as a function of pressure is given by
T = V R P
As you can see this is a linear graph(V/R is constant). If you calibrate it using water's boiling and freezing point, and make hundred divisions in the range, you will get accurate values of temperature for a linear change in pressure.
For the gas following Van der Waal's equation:
The temperature as a function of pressure is given by
T = V b R P + ( V b ) a R V 2
As you can see this is also a linear function(of the form T = m P + c ). Calibrating this with water's boiling point and freezing point will give the same temperature readings for linear change in pressure, just as before.